AiDot OREiN OL003 160CFM 40W Humidity Sensor Bathroom Exhaust Fan with Light- Dimensions 13.1'' x 13.1'' x 7.91''

Rating:
94 % of 100
$139.99 $199.99 $60
SKU
OL17003
For this product only
Rules
Redeem Now

Prices just DROPPED on the OREiN Bathroom Fan for the holidays! New users get an extra 10% off, automatically applied at checkout.

  • 【Bathroom Fan with Light】OREiN humidity sensing bathroom fan operates at 160 CFM speed and 1.0 sones for quiet operating performance to help control air quality, which is powerful enough for rooms up to 160 sq. ft. Bright 1500lm LED light will light your whole bathroom, providing high-quality lasting use for many years.
  • 【3CCT LED Light & Nightlight】You could preset your desired LED color temperature by sliding the toggle switch on the back of the bath fan shade: 3000k soft white, 4000k bright white or 5000k daylight. The 2200k nightlight will help you to find your way through the room in the dark.
  • 【Bathroom Fan with Humidity Sensor】Built in humidity sensor, the LED indicator light will be green in the humidity sensing mode, and the bathroom exhaust fan will automatically turn on when the humidity level in the room is above 60%. Power rating of 120-Volt/60 Hz.
  • 【Easy to Install】OREiN bathroom exhaust fan with light fits 11.81" x 11.02" x 9" ceiling construction with 6 inch duct and comes with fast bracket for secure and easy installation. Just mount the exhaust fan between ceiling joists with fast bracket, or nail/ screw it directly to the joist. Housing Dimensions 12.87" x 10.59" x 7.91". Light cover size is 13.1'' x 13.1". Duct Diameter: 6 inch.
  • 【Outstanding Performance】OREiN exhaust fan with light ensures comfort in your home by eliminating moisture and humidity in the bathroom. Ventilation fan was equipped with the high-quality components for long life as well as whisper quiet. Designed with simple construction featuring a modern style. Really ideal for residential construction. No steam leftover or fogged mirror after a really hot shower.
Size
160CFM 1500lm
100 CFM 1000lm
100 CFM 1500lm
(US) 2-5 days delivery | Free shipping over $10
$139.99 $199.99 $60
Payment Options
Trusted Delivery
  • amazon
delivery
Free & Fast Delivery
payment
Payment Security
support
Lifetime Customer Support
guarantee
60 Days Back Guarantee
delivery
Free & Fast Delivery
payment
Payment Security
support
Lifetime Customer Support
guarantee
60 Days Back Guarantee

Specification

Brand OREiN
Included Components ‎Bath Fan

OREiN - Illuminate for a Better Life

Make Life Much Easier with OREiN Humidity Sensing Ventilation Bathroom Fan

Clear the Air with the Right Bathroom Exhaust Fan

OREiN Bathroom Fan with Light & Humidity Sensor, 160 CFM, 1.0 Sones
 

  • NOTE: Please put the light and fan on separate switches, the bath fan includes a light that must to be operated separately with an additional switch or double switch;
  • Powerful 160-CFM blower to provide a safe and comfortable living environment;
  • Built-in 18W 1500Lm 3000/4000/5000K LED Light & 200Lm 2200K Nightlight;
  • DUCTING - Removable 6 inch metal duct with back draft prevention damper;
  • To prevent the insulation from sliding down the duct, wrap the connections a few times with HVAC tape;
  • NOTE: The Install Size is 11.81 in x 11.02 in. Hold the housing up to the hole to check that your fan fits. If the hole is too small, trace the housing onto the ceiling and then cut the ceiling with a keyhole saw. If the original hole is too big, you’ll need to patch the ceiling. Cut a piece of drywall to make the ceiling hole the right size for your fan. Attach the drywall filler to a larger piece of wood; set it in the hole and drive screws through the ceiling into the wood. The patched areas can be repaired with spackling compound later.
  • Important: An insulated duct will help prevent condensation when the warm air from the bathroom meets the cold duct in the attic. To prevent the insulation from sliding down the duct, wrap the connections a few times with HVAC tape;
  • NOTICE: If the light or the fan do not work, please make sure that the cables to the light and fan are properly connected. And this product only works with 120V;
    That it is common practice in heating and ventilation systems using sheet metal ductwork and fittings or flexible duct work tubing to use duct tape or aluminum tape to ensure air tight seals and improve efficiency.
Compare with Similar Items
Name
Lighting Dimension
Housing Dimension
Gross Weight
Fan power
Light power
Voltage
Motor
Size
CFM
Sone
Main Light
Night Light
CCT
Capability
13.1*13.1*4in
12.87*10.59*7.91 in
8.2kg
40W
18W
120
AC
6in
160CFM
1
1500lm
200lm/2200K
3000/4000/5000K
The fan will automaticlly turn on when the humidity level reaches 60%.
10.1*10.1*2.5in
7.68*7.55*6.42in
4.9Kg
25W
12W
120
DC
4in
100CFM
<1.5
1000lm
200lm/2200K
3000/4000/5000K
/
13.1*13.1*4in
12.87*10.59*7.91 in
8.2kg
40W
20W
120
AC
6in
110/160CFM
1
1500lm
200lm/2700K
2700/4000/6500K
7-color LED light and built-in Bluetooth speaker

Reviews 104

Customer Images
Write Your Own Review
Customer Reviews

FAQ

How to adjust the ceiling hole?
If the hole is too small, trace the housing onto the ceiling and then cut the ceiling with a keyhole saw. If the hole is too big, you’ll need to patch the ceiling. Cut a piece of drywall to make the ceiling hole the right size for your fan.
The light does not work.
Make sure you are using a non-dimmer switch and that the switch contact is good; Make sure that the cables to the light and fan are properly connected. Only works with 120V; Make sure the wire connecting the lampshade to the housing is well inserted.
The fan seems louder than it should.
Check damper to ensure it is opening & closing properly; Be sure do not have any sharp bends in duct closer than 18 in. to the fan discharge; Use recommended size ducting to reduce fan noise; Be sure the fan is securely attached to ceiling joists.
The fan is not clearing the room.
Be sure a door or window is slightly ajar or opened to allow airflow; Be sure the fan is vented with the right size duct; The deep corrugations of flexible ducting may easily flex into the opening and block the damper, please use semi-rigid ducting.
How to prevent moisture buildup?
Avoid venting through a soffit vent or ridge vent. The warm air will exhaust out the duct and enter back into the attic through it; An insulated duct will help prevent condensation when the warm air from the bathroom meets the cold duct in the attic.

User Manual

spring deal