The OREiN bathroom exhaust fan with light clears the air with a low profile, streamline design. Say good-bye to unsightly standard grilles that catch dust and debris and can be a hassle to clean. The OREiN bathroom exhaust fan features a sleek, modern design that stays cleaner for longer with fewer vent slots to clean and design that coordinates with any decor. Designed for retrofit, remodel, and replacement, the OREiN fan features easy installation from the room side, for spaces with no attic access. The fast bracket and 6-inch duct connector make installation secure and flexible for almost any installation challenge, especially for rooms on the first floor or basement. Each carton comes with a precise template for accurate housing opening ceiling cut. The fast bracket provides a secure and neat finish.

(US) 2-5 days delivery | Free shipping over $10
Special Price $149.99 Regular Price $199.99 $50
Payment Options
Trusted Delivery
  • amazon
delivery
Free & Fast Delivery
payment
Payment Security
support
Lifetime Customer Support
guarantee
60 Days Back Guarantee
delivery
Free & Fast Delivery
payment
Payment Security
support
Lifetime Customer Support
guarantee
60 Days Back Guarantee

Specification

Brand OREiN
Color White
Product Dimensions 10.59"D x 12.87"W x 7.91"H
Room Type Bathroom
Special Feature Humidity Sensor
Recommended Uses For Product Exhausting
Noise Level 1 Sones
Wattage 40 watts
Air Flow Capacity 160 Cubic Feet Per Minute
Voltage 120 Volts

Features

ETL Listed Mark (Intertek)


ENERGY STAR certified


HVI certifies ventilating fan


  • 160 CFM airflow effectively eliminates moisture, reducing the risk of mold or mildew in bathrooms up to 160 sq. ft.
  • 1.0 Sones for ultra-quiet performance
  • Easy to install from the room side for convenient retrofit into spaces with no attic access.
  • Modern, Sleek Design. The sleek design stays cleaner longer with fewer vent slots to collect dust and coordinates with any decor.
  • Fast bracket ensures secure and easy installation for both new construction and retrofit projects, especially for rooms on the first floor or basement.
  • 6-inch Duct Connector with Damper, Creates an airtight seal while connecting to the duct from below the ceiling.
  • ENERGY STAR® Certified, Ensures energy-efficient operation.
  • Fits 11.81" x 11.02" x 9" Ceiling Construction: Compatible with most ceiling structures.
  • UL Listed for Use in Insulated Ceilings (Type I.C.): HVI-2100 certified for safety.
  • 3-Year Limited Warranty: Ensures peace of mind with your purchase.
  • Built-in Humidity Sensor: Automatically turns on when the humidity level in the room is above 60%, with a green LED indicator light in the humidity sensing mode.
  • 3CCT LED Light & Nightlight: Preselect your desired LED color temperature: 3000K soft white, 4000K bright white, or 5000K daylight. The 2200K nightlight helps you navigate in the dark.

 

NO CUTTING OR PATCHING DRYWALL

Upgrade This OREiN Ventilation Fan

 

OREiN Universal Bathroom Exhaust Fan Upgrade Grille/Cover. This sleek, modern grille is designed to fit small, medium, and large size OREiN ventilation fans. It features a clean, bright white finish to match the most popular white ceiling paint colors.

 

 

Buy Now

Ever Wonder How Different Color Temperatures Look?

1500lm 5000K

1500lm 4000K

1500lm 3000K

200lm 2200K

Learn More Via Video

Reviews 23

Customer Images
Write Your Own Review
Customer Reviews

FAQ

How to adjust the ceiling hole?
If the hole is too small, trace the housing onto the ceiling and then cut the ceiling with a keyhole saw. If the hole is too big, you’ll need to patch the ceiling. Cut a piece of drywall to make the ceiling hole the right size for your fan.
The light does not work.
Make sure you are using a non-dimmer switch and that the switch contact is good; Make sure that the cables to the light and fan are properly connected. Only works with 120V; Make sure the wire connecting the lampshade to the housing is well inserted.
The fan seems louder than it should.
Check damper to ensure it is opening & closing properly; Be sure do not have any sharp bends in duct closer than 18 in. to the fan discharge; Use recommended size ducting to reduce fan noise; Be sure the fan is securely attached to ceiling joists.
The fan is not clearing the room.
Be sure a door or window is slightly ajar or opened to allow airflow; Be sure the fan is vented with the right size duct; The deep corrugations of flexible ducting may easily flex into the opening and block the damper, please use semi-rigid ducting.
How to prevent moisture buildup?
Avoid venting through a soffit vent or ridge vent. The warm air will exhaust out the duct and enter back into the attic through it; An insulated duct will help prevent condensation when the warm air from the bathroom meets the cold duct in the attic.